• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to secondary sidebar
  • Skip to footer
  • info@vsep.com
  • +1-775-783-7600
New Logic Research
  • Home
  • Technology
    • Benefits
    • VSEP System Components
    • Membrane Technology
    • Applications
    • FAQ
    • Pilot Testing
  • Products
    • Series i
      • i18 VSEP Filtration System
      • i36 VSEP Filtration System
      • i84 VSEP Filtration System
      • High Pressure Systems
    • Lab & Pilot Systems
      • Series B
      • Series LP
      • Series P50
      • Batch Titan® 1000
    • Spiral RO Systems
      • S-80 Spiral RO System
      • S-240 Spiral RO System
      • S-800 Spiral RO System
      • S-1600 Spiral RO System
      • S-3200 Spiral RO System
      • S-7200 Spiral RO System
      • S-9600 Spiral RO System
      • S-18000 Spiral RO System
      • S-28800 Spiral RO System
      • S-36000 Spiral RO System
    • VSEP Membrane Cleaners
      • NLR 103
      • NLR 202
      • NLR 404
      • NLR 505
      • NLR 550
      • NLR 707
      • NLR 757
      • NLR 758
      • NLR 759
  • Industries
    • Animal Protein and By-Products
      • Aquaculture Wastewater
      • Fish Meal Stickwater
      • Fish Processing Wastewater
      • Leather Tannery Wastewater
      • Rendering Wastewater Treatment
      • Slaughterhouse Wastewater
    • Biogas Effluent
    • Brine and Brackish Water
      • RO Reject / Brine Minimization
      • Zero Liquid Discharge (ZLD)
    • Food and Beverage
      • Beer Bottoms Filtration
      • Beverage Production
      • Bottled Water
      • Coffee Extract Dewatering
      • Cooked Corn Wastewater
      • Fruit Juice Clarification
      • Olive Processing
      • Palm Oil POME Treatment
      • Sugar Juice Clarification
      • Whey Wastewater
      • Winery Wastewater
    • Industrial Wastewater
      • Calcium Chloride Recovery
      • Colloidal Silica Dewatering
      • Glycol Recovery
      • Hot Rolled Steel Wastewater
      • Indigo Dye Wastewater
      • Laundry Wastewater
      • PET Recycling Wastewater
      • PFAS Remediation and Treatment
      • Sodium Sulfate Recovery
      • Textile Dye Wastewater
      • Yeast Wastewater
    • Landfill Leachate Treatment
      • PFAS Removal for Landfill Leachate
    • Manure Management
    • Metal Finishing Wastewater
      • Aluminum Can Wastewater
      • Anodizing Wastewater
      • Electroplating Wastewater
      • Galvanizing Wastewater
      • Powder Coating Wastewater
    • Mining and Metals
      • Acid Purification and Recycling
      • Copper Refining Wastewater
      • Gold Tailings Pond Water
      • Gypsum Stack Wastewater
      • Iron Tailings Pond Water
      • Lithium Extraction
      • Manganese Ferroalloy Wastewater
      • Phosphoric Acid Filtration
      • Platinum Group Metals
      • Rare Earth Elements
      • Red Mud Dewatering
      • Zinc Smelting Wastewater
    • Municipal Wastewater
      • Indirect Potable Reuse
      • POTW Discharge
      • Reclaimed Water Treatment
      • Remote Community Wastewater
    • Oil and Gas Applications
      • Algae Dewatering & Harvesting
      • Desalter Effluent
      • Drilling Mud Treatment
      • Fuel Storage Tank Water
      • Frac Water
      • Oily Wastewater
      • Produced Water
      • Slop Oil Treatment
      • Stripped Sour Water
    • Pigment Dewatering
      • Calcium Carbonate Dewatering
      • Carbon Black
      • Iron Oxide Pigment
      • Kaolin Clay Dewatering
      • Metal Chromate Pigment
      • Titanium Dioxide Filtration
    • Polymer Manufacturing
      • PVC Latex
    • Power Plant Effluent
      • Cooling Tower Blowdown
      • FGD Wastewater
      • Fly Ash Leachate Treatment
      • Nuclear Power
    • Pulp & Paper
      • Black Liquor
      • Box Plant Wastewater
      • End of Pipe Wastewater
      • Hardboard Wastewater
      • MDF Wastewater
      • Paper Coating Recovery
      • Whitewater Treatment
    • Semiconductor
      • Gallium Arsenide Wastewater
      • HF Wastewater
      • PCB Wastewater
      • Scrubber Wastewater
      • Ultrapure Water
      • Wafer Fabrication Wastewater
    • Stillage and Vinasse Dewatering
      • Glycerol Recovery from Stillage
  • Company
    • Careers
    • Contact
    • Distributors
    • Join our Mailing List
    • News
    • Privacy Policy
    • Sitemap
  • Downloads
    • Case Studies & Application Notes
    • Technical Articles Featuring VSEP
    • VSEP Brochure
    • VSEP Video Clips
    • VSEP System Drawings
    • New Logic Customer Forms

VSEP Industries

PVC Latex

PVC Latex Concentration / Dewatering with VSEP®

Reduce Spray Drying Energy Costs While Maintaining Latex Stability

Polyvinyl chloride (PVC) latex, also known as PVC dispersion resin, is produced through an emulsion or micro-suspension polymerization process where vinyl chloride monomer (VCM) is polymerized into extremely fine particles suspended in water. The resulting latex is widely used in the manufacture of synthetic leather, flooring, wall coverings, gloves, coatings, sealants, and plastisol products.

Following polymerization, PVC latex typically leaves the reactor at approximately 30-40% solids, with many facilities operating near 35% solids. At this concentration, large volumes of water must be removed before the material can be converted into dry dispersion resin. Traditionally, this load falls entirely on the spray dryer, one of the largest consumers of energy in a PVC latex plant.

The Challenge of Dewatering PVC Latex

PVC latex is notoriously difficult to filter using conventional membrane systems.

The latex particles are extremely fine, sticky, and deformable. As concentration increases, these particles rapidly accumulate on membrane surfaces, forming a dense cake layer that reduces permeate flow and eventually causes severe fouling. Conventional crossflow membrane systems often struggle to maintain economically viable flux rates when processing concentrated PVC latex.

In addition, maintaining latex stability is critical. The dispersants and surfactants present in the formulation keep the PVC particles separated and prevent agglomeration. If these stabilizing compounds are selectively removed during concentration, the latex can become unstable, resulting in viscosity increases, coagulation, and handling problems.

For additional information on PVC wastewater treatment see this article.

How VSEP® Solves the Problem

VSEP® (Vibratory Shear Enhanced Processing) technology creates intense shear waves directly at the membrane surface through high-frequency vibration.

Unlike traditional crossflow filtration, VSEP continuously disrupts the boundary layer where fouling normally develops. The shear generated at the membrane surface prevents PVC latex particles from accumulating and forming a filtration cake.

This allows VSEP systems to concentrate PVC latex to significantly higher solids concentrations while maintaining practical flux rates.

Typical Process

Why RO Membranes Work Best

In PVC latex service, membrane selection is critical.

While ultrafiltration (UF) membranes can retain the PVC particles, they often allow portions of the dispersant package to pass into the permeate stream. Loss of these stabilizing compounds can alter latex rheology and lead to instability during concentration.

For this reason, VSEP installations typically utilize reverse osmosis (RO) membranes. The RO membrane retains:

  • PVC latex particles
  • Dispersants
  • Surfactants
  • Colloidal materials
  • Other formulation ingredients

By maintaining the original chemistry of the latex, the concentrate remains stable, pumpable, and suitable for downstream spray drying.

Proven Commercial Applications

New Logic has successfully supplied VSEP systems for PVC latex concentration applications in:

  • Mexico
  • Japan
  • England

These systems have demonstrated the ability to concentrate reactor latex from approximately 35% solids to 50-60% solids prior to the spray dryer.

Lower Spray Dryer Operating Costs

The primary economic benefit is straightforward:

Every gallon of water removed by VSEP is a gallon that no longer needs to be evaporated thermally in the spray dryer.

Benefits include:

  • Reduced natural gas consumption
  • Reduced steam demand
  • Increased spray dryer throughput
  • Reduced operating costs
  • Lower greenhouse gas emissions
  • Deferred capital expansion of dryer capacity

Because membrane dewatering uses significantly less energy than thermal evaporation, the economics are often highly attractive for facilities operating large spray drying systems.

Additional Wastewater Applications

Beyond latex concentration, VSEP can also provide value elsewhere in the PVC latex plant.

Washdown Water Recovery

Equipment cleaning and reactor washdown streams often contain:

  • PVC latex solids
  • Dispersants
  • Surfactants
  • Residual product

VSEP can recover water for reuse while concentrating residual solids for disposal or potential product recovery.

Wastewater Treatment

PVC latex manufacturing wastewater may contain:

  • Suspended latex particles
  • Emulsifiers
  • Process chemicals
  • Residual vinyl chloride monomer

VSEP can remove suspended and colloidal materials while producing a clarified permeate stream. The system’s high rejection characteristics also provide an effective barrier to residual monomer and dissolved contaminants prior to discharge or further treatment.

A Better Approach to PVC Latex Concentration

For PVC latex producers, VSEP offers a proven method to reduce spray dryer energy consumption while overcoming the severe fouling challenges that limit conventional membrane systems.

By utilizing vibratory shear and RO membrane separation, VSEP can:

  • Concentrate PVC latex from approximately 35% solids to 50-60% solids
  • Maintain latex stability by retaining dispersants and surfactants
  • Reduce spray drying energy requirements
  • Increase plant throughput
  • Recover water from washdown operations
  • Improve wastewater treatment performance
  • Reduce overall operating costs

Pilot Testing and Performance Projections

New Logic offers pilot testing—including full‑scale demonstrations to evaluate treatment performance. Performance projections are based on measured pilot data, not nameplate assumptions. Every project is unique, so pilot testing is needed.

Pilot testing allows:

  • Verification of filtrate quality
  • Measurement of flux, recovery, and fouling behavior
  • Accurate operating cost projections
  • Measuring the concentration factor possible

Request a No‑Cost Performance Projection

Talk to a VSEP Expert 

VSEP has decades of experience treating some of the most challenging industrial wastewaters in the world.

Contact us today to learn how VSEP can transform your latex production system.

  • Request a Performance Projection: info@vsep.com
  • Learn about Pilot Testing Options: https://www.vsep.com/technology/pilot-testing/
  • Learn More About the Technology: https://www.vsep.com/technology/

Phone Number: 775-783-7600

About VSEP and New Logic Research

  • More than 450 industrial VSEP systems installed globally
  • Technology covered by U.S. and international patents
  • Used in food, beverage, wastewater, and agricultural applications
  • Engineering team with chemical, metallurgical, and mechanical engineering backgrounds

This page was prepared by New Logic Research’s senior process engineers with backgrounds in membrane process engineering. Our team has over 30 years of direct experience designing, building, and piloting high‑shear membrane systems for industrial applications.

 

Frequently Asked Questions

Why is PVC latex concentrated before spray drying?

PVC latex typically exits the polymerization process at approximately 35% solids. Concentrating the latex to 50-60% solids before the spray dryer significantly reduces the amount of water that must be evaporated thermally, lowering energy consumption and operating costs while increasing spray dryer throughput.

Why use VSEP instead of a conventional membrane system?

PVC latex is highly prone to membrane fouling because the fine latex particles are sticky and readily form a cake layer on conventional membrane surfaces. VSEP’s high-frequency vibration creates intense shear at the membrane surface, preventing particle buildup and maintaining higher filtration rates.

What solids concentration can VSEP achieve?

Commercial VSEP installations have concentrated PVC latex from approximately 35% solids to 50-60% solids prior to spray drying. Actual concentration levels depend on latex formulation, viscosity, and product requirements.

Why are RO membranes used instead of UF membranes?

While ultrafiltration membranes typically retain PVC particles, they may allow dispersants and surfactants to pass into the permeate stream. Depletion of these stabilizing compounds can cause latex instability, increased viscosity, and potential coagulation. Reverse osmosis membranes retain both the PVC particles and the stabilizing additives, helping maintain product quality.

Will VSEP affect latex stability?

No. VSEP systems used for PVC latex concentration typically employ RO membranes that retain the latex particles, dispersants, surfactants, and other formulation components. The concentrate remains stable, fluid, and suitable for downstream spray drying.

Where has VSEP been used for PVC latex applications?

New Logic has successfully installed VSEP systems for PVC latex concentration applications in Mexico, Japan, and England, where the systems are used to reduce the energy load on spray dryers and lower overall operating costs.

Can VSEP be used elsewhere in a PVC latex plant?

Yes. In addition to latex concentration, VSEP can be used to treat:

  • Reactor and equipment washdown water
  • Product recovery streams
  • Process wastewater
  • Latex-containing effluent streams
  • Water reuse applications

Can VSEP help remove residual vinyl chloride monomer (VCM)?

Yes. VSEP membranes provide high rejection of suspended and dissolved contaminants and can serve as an additional barrier for residual monomer and other wastewater constituents before discharge, reuse, or further treatment.

What are the primary economic benefits of VSEP?

Key benefits include:

  • Reduced spray dryer energy consumption
  • Lower natural gas or steam usage
  • Increased production capacity
  • Reduced operating costs
  • Water recovery and reuse opportunities
  • Lower wastewater treatment costs
  • Reduced greenhouse gas emissions

How is VSEP different from thermal evaporation?

VSEP removes water using membrane separation rather than heat. Membrane concentration generally requires significantly less energy than evaporating the same volume of water in a spray dryer, making it an attractive pretreatment step for PVC latex manufacturers seeking lower operating costs and improved sustainability.

 

Primary Sidebar

Industries
  • Animal Protein and By-Products
    Aquaculture WastewaterFish Meal StickwaterFish Processing WastewaterLeather Tannery WastewaterRendering Wastewater TreatmentSlaughterhouse Wastewater
  • Biogas Effluent
  • Brine and Brackish Water
    RO Reject / Brine MinimizationZLD
  • Food and Beverage
    Beer Bottoms FiltrationBeverage ProductionBottled WaterCoffee Extract DewateringCooked Corn WastewaterFruit Juice ClarificationOlive ProcessingPalm Oil POME TreatmentSugar Juice ClarificationWhey WastewaterWinery Wastewater
  • Industrial Wastewater
    Calcium Chloride RecoveryColloidal Silica DewateringGlycol RecoveryHot Rolled Steel WastewaterIndigo Dye WastewaterLaundry WastewaterPET Recycling WastewaterPFAS Remediation and TreatmentSodium Sulfate RecoveryTextile Dye WastewaterYeast Wastewater
  • Landfill Leachate Treatment
    PFAS Removal for Landfill Leachate
  • Manure Management
  • Metal Finishing Wastewater
    Aluminum Can WastewaterAnodizing WastewaterElectroplating WastewaterGalvanizing WastewaterPowder Coating Wastewater
  • Mining and Metals
    Acid Purification and RecyclingCopper Refining WastewaterGold Tailings Pond WaterGypsum Stack WastewaterIron Tailings Pond WaterLithium ExtractionManganese Ferroalloy WastewaterPhosphoric Acid FiltrationPlatinum Group MetalsRare Earth ElementsRed Mud DewateringZinc Smelting Wastewater
  • Municipal Wastewater
    Indirect Potable ReusePOTW DischargeReclaimed Water TreatmentRemote Community Wastewater
  • Oil and Gas Applications
    Algae Dewatering & HarvestingDesalter EffluentDrilling Mud TreatmentFuel Storage Tank WaterFrac WaterOily WastewaterProduced WaterSlop Oil TreatmentStripped Sour Water
  • Pigment Dewatering
    Calcium Carbonate DewateringCarbon BlackIron Oxide PigmentKaolin Clay DewateringMetal Chromate PigmentTitanium Dioxide Filtration
  • Polymer Manufacturing
    PVC Latex
  • Power Plant Effluent
    Cooling Tower BlowdownFGD WastewaterFly Ash Leachate TreatmentNuclear Power
  • Pulp & Paper
    Black LiquorBox Plant WastewaterEnd of Pipe WastewaterHardboard WastewaterMDF WastewaterPaper Coating RecoveryWhitewater Treatment
  • Semiconductor
    Gallium Arsenide WastewaterHF WastewaterPCB WastewaterScrubber WastewaterUltrapure WaterWafer Fabrication Wastewater
  • Stillage and Vinasse Dewatering
    Glycerol Recovery from Stillage

Secondary Sidebar

New Logic Research
  • From chemical processing and manure wastewater to pure drinking water, VSEP systems can be configured to meet the needs of virtually any industry application.
  • Contact a Sales Engineer
    • This field is for validation purposes and should be left unchanged.
  • Subscribe to
    our newsletter

    Address:
    2527 Aviation Way
    Minden, NV 89423

    775-783-7600
    info@vsep.com

    Copyright © New Logic Research All Rights Reserved.