• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to secondary sidebar
  • Skip to footer
  • info@vsep.com
  • +1-775-783-7600
New Logic Research
  • Home
  • Technology
    • Benefits
    • VSEP System Components
    • Membrane Technology
    • Applications
    • FAQ
    • Pilot Testing
  • Products
    • Series i
      • i18 VSEP Filtration System
      • i36 VSEP Filtration System
      • i84 VSEP Filtration System
      • High Pressure Systems
    • Lab & Pilot Systems
      • Series B
      • Series LP
      • Series P50
      • Batch Titan® 1000
    • Spiral RO Systems
      • S-80 Spiral RO System
      • S-240 Spiral RO System
      • S-800 Spiral RO System
      • S-1600 Spiral RO System
      • S-3200 Spiral RO System
      • S-7200 Spiral RO System
      • S-9600 Spiral RO System
      • S-18000 Spiral RO System
      • S-28800 Spiral RO System
      • S-36000 Spiral RO System
    • VSEP Membrane Cleaners
      • NLR 103
      • NLR 202
      • NLR 404
      • NLR 505
      • NLR 550
      • NLR 707
      • NLR 757
      • NLR 758
      • NLR 759
  • Industries
    • Animal Protein and By-Products
      • Aquaculture Wastewater
      • Fish Meal Stickwater
      • Fish Processing Wastewater
      • Leather Tannery Wastewater
      • Rendering Wastewater Treatment
      • Slaughterhouse Wastewater
    • Biogas Effluent
    • Brine and Brackish Water
      • RO Reject / Brine Minimization
      • Zero Liquid Discharge (ZLD)
    • Food and Beverage
      • Beer Bottoms Filtration
      • Beverage Production
      • Bottled Water
      • Coffee Extract Dewatering
      • Cooked Corn Wastewater
      • Fruit Juice Clarification
      • Olive Processing
      • Palm Oil POME Treatment
      • Sugar Juice Clarification
      • Whey Wastewater
      • Winery Wastewater
    • Industrial Wastewater
      • Calcium Chloride Recovery
      • Colloidal Silica Dewatering
      • Glycol Recovery
      • Hot Rolled Steel Wastewater
      • Indigo Dye Wastewater
      • Laundry Wastewater
      • PET Recycling Wastewater
      • PFAS Remediation and Treatment
      • Sodium Sulfate Recovery
      • Textile Dye Wastewater
      • Yeast Wastewater
    • Landfill Leachate Treatment
      • PFAS Removal for Landfill Leachate
    • Manure Management
    • Metal Finishing Wastewater
      • Aluminum Can Wastewater
      • Anodizing Wastewater
      • Electroplating Wastewater
      • Galvanizing Wastewater
      • Powder Coating Wastewater
    • Mining and Metals
      • Acid Purification and Recycling
      • Copper Refining Wastewater
      • Gold Tailings Pond Water
      • Gypsum Stack Wastewater
      • Iron Tailings Pond Water
      • Lithium Extraction
      • Manganese Ferroalloy Wastewater
      • Phosphoric Acid Filtration
      • Platinum Group Metals
      • Rare Earth Elements
      • Red Mud Dewatering
      • Zinc Smelting Wastewater
    • Municipal Wastewater
      • Indirect Potable Reuse
      • POTW Discharge
      • Reclaimed Water Treatment
      • Remote Community Wastewater
    • Oil and Gas Applications
      • Algae Dewatering & Harvesting
      • Desalter Effluent
      • Drilling Mud Treatment
      • Fuel Storage Tank Water
      • Frac Water
      • Oily Wastewater
      • Produced Water
      • Slop Oil Treatment
      • Stripped Sour Water
    • Pigment Dewatering
      • Calcium Carbonate Dewatering
      • Carbon Black
      • Iron Oxide Pigment
      • Kaolin Clay Dewatering
      • Metal Chromate Pigment
      • Titanium Dioxide Filtration
    • Polymer Manufacturing
    • Power Plant Effluent
      • Cooling Tower Blowdown
      • FGD Wastewater
      • Fly Ash Leachate Treatment
      • Nuclear Power
    • Pulp & Paper
      • Black Liquor
      • Box Plant Wastewater
      • End of Pipe Wastewater
      • Hardboard Wastewater
      • MDF Wastewater
      • Paper Coating Recovery
      • Whitewater Treatment
    • Semiconductor
      • Gallium Arsenide Wastewater
      • HF Wastewater
      • PCB Wastewater
      • Scrubber Wastewater
      • Ultrapure Water
      • Wafer Fabrication Wastewater
    • Stillage and Vinasse Dewatering
      • Glycerol Recovery from Stillage
  • Company
    • Careers
    • Contact
    • Distributors
    • Join our Mailing List
    • News
    • Privacy Policy
    • Sitemap
  • Downloads
    • Case Studies & Application Notes
    • Technical Articles Featuring VSEP
    • VSEP Brochure
    • VSEP Video Clips
    • VSEP System Drawings
    • New Logic Customer Forms

News

Vibes Newsletter – November 2026

October 19, 2026

Printable PDF

Vibes Newsletter

The PFAS Circular Reference: POTW Biosolids to Landfill and Leachate Back to the POTW

For years, municipal wastewater treatment plants (POTWs) and landfills have functioned as partners in managing society’s waste streams. Today, however, PFAS is exposing an feedback loop between the two industries that could fundamentally change how biosolids and landfill leachate are managed. PFAS chemicals enter a POTW from industrial discharges, households, and commercial sources. These do not simply disappear during treatment. Most of it simply passes through the treatment plant, but, much of it partitions into the settled biosolids. Those biosolids are sometimes disposed of in municipal solid waste landfills. Once in a landfill, PFAS from the biosolids slowly migrate into the leachate generated by moisture moving through the waste mass. The irony is that much of that leachate is then hauled right back to the same POTW that originally produced the biosolids.

The result is a circular loop. Landfills receive PFAS through biosolids and consumer wastes, PFAS enters the leachate, and the leachate is transported back to wastewater plants. PFAS accumulates in newly generated biosolids, which may again be sent to landfills. Many POTWs across the country are tightening acceptance limits for landfill leachate or reevaluating whether they can continue accepting it at all because of the PFAS liability.

Evidence suggests that landfills receiving biosolids exhibit some of the highest PFAS concentrations in leachate. Michigan’s statewide landfill investigations reported an active landfill with total PFAS concentrations reaching 93,720 ng/L. Active facilities consistently exhibiting higher PFAS levels than older, closed landfills. Even more striking were results from Washington State’s landfill study, where regulators reported an average total PFAS concentration of 32,220 ng/L and a concentration at one unnamed landfill of 173,029 ng/L. State officials noted that this concentration represented the highest municipal landfill leachate PFAS level their laboratory had ever observed.

Regulators are paying close attention. EPA’s national landfill study found PFAS present in approximately 95 percent of leachate samples collected from more than 200 landfills and identified 63 different PFAS compounds. Based on those findings, EPA announced plans to revise the Landfills Effluent Guidelines and develop new PFAS-related discharge requirements for landfill leachate. Several landfills repeatedly appear in PFAS investigations and discussions surrounding leachate management, including Coventry Landfill in Vermont, Seneca Meadows Landfill in New York, Hakes C&D Landfill in New York, Ontario County Landfill in New York, Hyland Landfill in New York, and Cedar Hills Landfill in Washington.

The next question is: if POTWs increasingly restrict leachate disposal because of PFAS, will landfills begin restricting biosolids acceptance for the same reason? As EPA regulations move forward, both industries will be forced to confront a reality: PFAS is forever and does not go away. It is simply being moved from one place to another.


The River That Built Civilization Is Quietly Fading

For thousands of years, the Euphrates River has been the artery of life in the Middle East. It carved through the Fertile Crescent, nourished the earliest cities of Mesopotamia, and supported the rise of agriculture, law, and written language, the very foundations of civilization. Today, that same river is shrinking before our eyes. Travel along stretches of the Euphrates now, and the contrast is stark. Channels once wide and deep are reduced to narrow streams. Exposed banks crack under relentless heat. In parts of Iraq and Syria, the river flows at only a fraction of its historical volume, with some downstream sections losing up to 70–90% of flow. Scientists warn that if current trends continue, large portions of the river could effectively dry up by around 2040.

The causes are not mysterious. Upstream dam construction, particularly in Turkey, has dramatically reduced the water reaching Syria and Iraq. At the same time, prolonged droughts, higher temperatures, and increased evaporation, are further shrinking the river’s supply. Add to this the heavy demand from agriculture, which consumes the majority of available water, and a growing population, and the outcome becomes inevitable: less water, spread thinner every year.

The consequences extend far beyond shrinking shorelines. As flow declines, water quality deteriorates. Slower-moving water concentrates salts, pollutants, and agricultural runoff. In Iraq, this has contributed to outbreaks of waterborne diseases such as cholera and typhoid, highlighting a growing public health crisis. What was once a life-giving resource is becoming, in places, unsafe to drink. Economic impacts are equally severe. Farmers along the Euphrates are losing crops as irrigation systems fail. Fisheries are collapsing as ecosystems degrade. Reduced water also limits hydropower and industrial activity, straining already fragile economies. Entire communities are being forced to adapt or leave.

And the Euphrates is not alone. Around the world, major rivers are facing similar pressures. The Colorado River in the United States is so over-allocated that it often no longer reaches the sea. The Yellow River in China has repeatedly run dry before its outlet due to overuse. Even vast systems like the Amazon and Yangtze have recently experienced record low levels during extreme droughts. These rivers, like the Euphrates, reveal a global pattern: demand is outpacing supply.

What makes the situation in Mesopotamia especially poignant is its history. This is the “cradle of civilization,” where the control of water once enabled human progress. Now, mismanagement of that same resource threatens regression. There is still time to change course, but only if action is taken. Water conservation must become a priority at every level, from agriculture to urban use. Advanced treatment and reuse of wastewater will be essential. Infrastructure must shift from simply extracting water to managing it sustainably. The lesson of the Euphrates is simple and urgent: civilization began with water, but its future may depend on whether we can learn to live within its limits before it is too late.


When Water Collected at a Construction Site Becomes a Water Treatment Project

When people think about construction site stormwater compliance, they usually picture silt fences, sediment ponds, and runoff controls designed to keep soil from washing into nearby streams. Others are familiar with industrial stormwater regulations, where rainwater contacts fly ash, coal piles, scrap metal, or landfill waste and must be managed before discharge. Stormwater that comes from city streets and sidewalks is largely not regulated. Not all industrial sites are required to collect and treat stormwater. What is less widely understood is that many construction projects encounter groundwater, springs, or seepage during excavation, and once that water is collected, it becomes a regulated stream subject to stringent permit requirements no matter its quality or quantity.

This situation is common in mining, pipeline construction, transportation projects, and utility installations. As soon as any dirt is moved, the water contacting it becomes a liability. In some locations, groundwater may be just below the surface. Excavation activities can intercept aquifers, springs, or groundwater that naturally existed before construction began. Once the water is captured, regulations for discharge apply under Clean Water Act. Many contractors are surprised to learn that this includes water that is not even contaminated by construction activities at all. The groundwater may may already contain elevated concentrations of dissolved minerals and trace elements. Contractors may be required to treat spring water or groundwater that has existed for decades and has naturally attenuated into local surface waters.

Conventional construction dewatering treatment systems are typically designed to remove sediment, reduce turbidity, and control pH. These methods work well when the primary concern is suspended solids. However, dissolved contaminants such as boron and arsenic cannot be effectively removed through settling tanks, filtration systems, or clarifiers. In these cases, advanced treatment technologies may be required to achieve permit limits. Reverse osmosis often becomes one of the few practical solutions capable of reducing dissolved constituents to acceptable discharge concentrations.

The challenge does not end with treatment. New construction sites rarely have access to municipal sewer systems capable of accepting large volumes of concentrate generated by RO systems. As a result, many projects effectively become zero-liquid-discharge (ZLD) projects. Concentrate must either be hauled for disposal or further reduced through evaporation systems, both of which can be costly.

This is where membrane concentration technologies can significantly impact project economics. A properly designed RO system may recover the majority of the feed water, but, a secondary VSEP RO system can recover much of the remaining volume. VSEP can transform what would be an enormous disposal burden into a manageable stream. For construction projects encountering challenging groundwater, the difference between conventional treatment and high-recovery membrane systems can determine whether a project remains economically and environmentally viable.


How a Reverse Osmosis Membrane Is Made

Most people think of a reverse osmosis membrane as a simple sheet that separates salt from water. In reality, it is the product of a remarkably sophisticated manufacturing process that combines polymer chemistry, precision coating technology, and nanometer-scale engineering. The journey begins with a nonwoven polyester fabric. This material serves as the membrane’s backbone, providing the mechanical strength needed to withstand years of operation inside pressure vessels. Alone, however, the fabric cannot filter anything. To create a membrane support, manufacturers coat it with a liquid solution with the consistency of honey containing polyethersulfone (PES), a high-performance engineering polymer dissolved in a solvent.

The coated fabric then enters a water bath, where the first critical transformation occurs. Water rapidly diffuses into the PES polymer film while the solvent diffuses out. As the solvent leaves, the PES becomes insoluble and precipitates into a solid structure. This phenomenon, known as phase inversion, creates a highly porous support layer filled with microscopic channels that allow water to flow with very little resistance. Although no new chemical bonds are formed during this step, the liquid polymer penetrates the fabric and locks around the polyester fibers as it solidifies, creating a durable mechanical bond.

After phase inversion, the membrane passes through a series of washing tanks to remove any remaining solvent. The resulting composite now consists of a polyester backing and a porous PES support, but it still lacks the thin skin responsible for salt rejection. The next step is interfacial polymerization. The porous PES support is saturated with an aqueous solution containing m-phenylenediamine (MPD), a diamine monomer. Excess solution is removed, and the membrane is then immediately exposed to an organic solution containing trimesoyl chloride (TMC).

When these two chemicals meet, a reaction occurs almost instantaneously. The amine groups of MPD react with the acid chloride groups of TMC, forming an ultrathin, highly crosslinked aromatic polyamide layer. Remarkably, the membrane’s selective barrier is only a few hundred nanometers thick, yet it performs nearly all of the desalination work. Following polymerization, excess chemicals are removed and the membrane enters a curing oven. Exposure to elevated temperatures for several minutes stabilizes the polyamide structure, promotes additional crosslinking, and improves long-term performance. A final washing step removes residual monomers, reaction byproducts, and traces of solvent before the membrane is preserved and wound into large rolls.

One distinctive characteristic of many RO membranes is their rough, “ridge-and-valley” surface. This texture develops because interfacial polymerization occurs so rapidly that localized differences in monomer concentration create uneven growth patterns. Modern low-fouling membranes often appear smoother because manufacturers carefully control diffusion rates, reaction conditions, and surface modifications to produce a smoother more uniform polyamide film. The result is an elegant three-layer composite: polyester for strength, polyethersulfone for support, and an ultrathin polyamide barrier that makes desalination and water reuse possible. Behind every gallon of purified water lies a fascinating story of chemistry and engineering working together at the nanoscale.


Lake Mead Reaches a Historic Low: What It Means for Water Users Across the Southwest

For the past two decades, water managers have warned that declining storage in the Colorado River system would eventually force fundamental changes in how water is allocated throughout the Southwest. That future is no longer theoretical. Lake Mead, the nation’s largest reservoir, has now fallen to approximately 1,039 feet above sea level, placing it at the lowest level in history and below the  lows reached in 2022. The reservoir currently holds only about 25% of its designed storage capacity, underscoring the imbalance between water supply and demand across the Colorado River Basin.

The significance of Lake Mead’s elevation extends far beyond reservoir storage. Under the operating guidelines for the Colorado River, specific elevation thresholds trigger mandatory reductions in water deliveries to Arizona, Nevada, Mexico, and eventually additional users throughout the Lower Basin. The first shortage trigger, known as Tier 1, occurs at 1,075 feet. Tier 2 occurs at 1,050 feet, while Tier 3 is reached at 1,025 feet. Lake Mead is currently below both the Tier 1 and Tier 2 thresholds and only about 14 feet above the Tier 3 trigger level.

For industrial water users, Tier 3 represents a particularly important benchmark. At that level, substantially deeper mandatory cutbacks would be imposed on Lower Basin users. Arizona would experience the largest reductions due to the priority structure of Colorado River water rights, while Nevada and Mexico would also absorb significant allocation cuts. Although California’s senior water rights provide some protection compared with other Lower Basin users, continued declines would increase pressure for conservation measures, negotiated reductions, and operational changes affecting agricultural and industrial users alike.  Another concern is proximity to power generation thresholds at Hoover Dam. As reservoir elevations decline, hydropower generation becomes less efficient and operational flexibility is reduced. While Lake Mead remains above minimum power pool levels, the margin is narrowing and efficiency is dropping compared with historical conditions.

The situation at Lake Mead also mirrors conditions at Lake Powell, the upstream reservoir that serves as a critical balancing storage facility for the Colorado River system. Both reservoirs have experienced dramatic declines over the past two decades as prolonged drought, reduced runoff efficiency, and persistent water demand have reduced available storage. While temporary recoveries occurred following strong snowpack years, neither reservoir has returned to levels that would eliminate long-term supply concerns. The health of Lake Powell directly influences releases into Lake Mead, making the two reservoirs operationally inseparable.

For facilities in California, Arizona, and Nevada, the key takeaway is that future water availability is no longer guaranteed. Reservoir elevations, shortage tiers, interstate negotiations, and basin-wide conservation programs are becoming increasingly important business variables. With Lake Mead now at a historic low and approaching the Tier 3 threshold, water reliability planning, conservation investments, water reuse, and alternative supply strategies should be considered essential components of long-term operational resilience.


FGD Captures Pollutants. VSEP Prevents Their Release

Natural gas and coal take very different paths through the combustion process. Natural gas consists primarily of methane, along with small amounts of other hydrocarbons. Any sulfur compounds present are typically removed during gas processing before the fuel reaches the power plant. Coal, however, contains sulfur along with a wide range of naturally occurring minerals, metals, and trace elements that enter the combustion with the fuel. When coal is burned, sulfur is oxidized during combustion. The primary reaction forms sulfur dioxide: S + O2 → SO2. A smaller fraction is further oxidized to sulfur trioxide: 2 SO2 + O2 → 2 SO3

These sulfur oxides are environmentally significant because they contribute to the formation of sulfuric acid in the atmosphere, which can lead to acid rain, regional haze, and fine particulate formation. Controlling sulfur emissions became one of the first major environmental challenges for the coal-fired power industry. The industry’s solution was the widespread installation of wet limestone flue gas desulfurization (FGD) scrubbers. In a wet scrubber, flue gas is contacted with a recirculating slurry of finely ground limestone (CaCO₃). Sulfur dioxide dissolves into the slurry and reacts with the limestone to form calcium sulfite: SO2 + H2O + CaCO3 → CaSO3 + CO2 + H2O

Modern scrubbers employ forced oxidation by injecting air into the reaction tank. Oxygen converts calcium sulfite into calcium sulfate, commonly known as gypsum: CaSO3 + ½ O2 + 2 H2O → CaSO4·2H2O. The resulting gypsum is removed as a solid byproduct, effectively transferring sulfur from the flue gas into a manageable solid stream.

The scrubber does more than capture sulfur. As flue gas passes through the absorber, many trace contaminants are also transferred from the air phase into the aqueous phase. Selenium, arsenic, mercury, chlorides, and other constituents accumulate in the scrubber liquor and eventually report to the FGD wastewater stream. In effect, the scrubber functions as a large mass transfer system that moves pollutants from the atmosphere into water. This shift creates the next environmental challenge. While sulfur air emissions are now controlled, the resulting wastewater must be treated before discharge. Proposed EPA Effluent Limitation Guidelines (ELGs) place stringent requirements on the removal of selenium, arsenic, mercury, and other pollutants from FGD wastewater.

As the industry enters this second phase of environmental protection, advanced treatment technologies are becoming essential. VSEP reverse osmosis (RO) systems are being implemented to treat FGD wastewater and achieve compliance with increasingly demanding ELG requirements. By concentrating dissolved contaminants and producing high-quality permeate suitable for reuse or discharge, VSEP helps extend the environmental benefits of wet scrubbers beyond air quality protection and into surface water protection.

The first generation of environmental controls removed sulfur from the stack. The next generation will ensure that the pollutants captured from the air never reach rivers, lakes, and groundwater, completing the transition from emissions control to comprehensive environmental stewardship.


The Unsung Heroes Behind Every Successful Plant

When a power plant is producing electricity without interruption, or a biogas facility is meeting every environmental requirement without issue, nobody thinks about the operators behind the scenes. The lights stay on, compliance reports are clean, equipment hums along, and everything appears effortless. But those who work in industrial operations know the truth. The operator is often the last line of defense between stability and chaos. Every shift begins with the understanding that something unexpected could happen. A pressure spike. A pump failure. A sensor malfunction. A process upset that no one saw coming. The challenge is not simply responding to problems. It is anticipating them before they occur. The best operators are constantly reading the subtle signs of a system, looking for patterns, recognizing abnormalities, and making adjustments long before a situation becomes critical.

In many ways, operators are like physicians monitoring a patient in intensive care. They watch countless indicators, interpret changing conditions, and make decisions that keep the entire system healthy and stable. Their success is measured by the absence of problems, which is perhaps why their contributions so often go unnoticed. Ironically, when everything is working perfectly, operators receive little recognition. But, when something goes wrong, they are the ones in the hot seat.

It is a role that demands technical expertise, calm judgment, persistence, and resilience. Day after day, operators carry the responsibility of protecting equipment, production, environmental compliance, and public safety. They work through nights, weekends, storms, holidays, and emergencies. They make difficult decisions under pressure and often solve problems that no manual could have predicted. It is no surprise that burnout can become a very real risk. Retaining experienced operators is one of the greatest challenges many facilities face today, yet losing that knowledge and experience can place an entire operation at risk.

At New Logic, we understand these realities because we work with operators every day. We know that discharge compliance and plant uptime are not just performance metrics. They represent real people carrying real responsibilities. That is why our mission extends far beyond supplying treatment equipment. We are committed to making operators’ jobs easier, reducing stress wherever possible, and providing the support they need to succeed. Our commitment begins with extensive hands-on training and continues for the life of the system through free technical support. We equip our systems with remote-access capabilities so that troubleshooting and process optimization can happen in real time. When challenges arise, operators do not have to face them alone.

The industrial world depends on people who rarely receive the recognition they deserve. They are the quiet professionals who stand watch, solve problems, and keep critical facilities running day after day. To every operator working the control room, walking the plant floor, and protecting the operation through another shift: thank you. You are the unsung heroes of our industry, and at New Logic, supporting you is a responsibility we take very seriously.


The Constant Tug-of-War Inside Every Drop of Water

Operators of reverse osmosis systems, evaporators, cooling towers, and heat exchangers spend a great deal of time thinking about scale. Calcium carbonate, gypsum, silica, and other minerals can suddenly appear on membranes and heat transfer surfaces, reducing performance and increasing operating costs. While scaling often seems like an equipment problem, its true origins lie in thermodynamics. Understanding solubility is really about understanding the ongoing battle between dissolved and solid phases that takes place in every water treatment system. Many people think of substances as either soluble or insoluble. In reality, virtually everything has some degree of solubility in water. Even gold, one of the most chemically stable materials on Earth, can dissolve in pure water at extremely low concentrations. The reason is that water is never perfectly static. Atoms and ions are constantly leaving solid surfaces and entering solution, while dissolved species simultaneously return to and rejoin the solid. The key question is not whether a substance can dissolve, but how much can dissolve before equilibrium is reached.

That equilibrium is governed by a balance between two powerful forces. On one side is the crystal itself. A mineral crystal represents a highly organized, low-energy structure in which atoms are arranged in a stable configuration. Nature generally favors these low-energy states. On the other side is dissolved disorder. When ions leave the crystal and disperse throughout the water, randomness increases. This increase in disorder, known as entropy, favors dissolution. Nature favors low-energy and disorder at the same time and this is what governs equilibrium. The solubility limit occurs at the point where these opposing tendencies are perfectly balanced. At equilibrium, minerals continue dissolving and precipitating simultaneously, but the overall concentration remains unchanged.

This balance explains why operating conditions can dramatically influence scale formation. Temperature, for example, changes the energy relationship between solid and dissolved phases. Calcium carbonate exhibits reverse solubility, meaning it becomes less soluble as temperature rises. This is why hot surfaces in boilers, evaporators, and heat exchangers are particularly vulnerable to carbonate scale. Silica often behaves differently, becoming more soluble at elevated temperatures but precipitating as water cools downstream.

Concentration is equally important. In reverse osmosis systems, water passes through the membrane while dissolved minerals remain behind. As concentrations increase inside the membrane array, the dissolved state becomes less favorable. Eventually the equilibrium shifts, and minerals begin organizing into crystals.

The same principle applies to pH changes, pressure shifts, and chemical interactions that alter water chemistry. Whenever operating conditions make the solid phase more energetically favorable than the dissolved phase, precipitation occurs. Ultimately, scale is not a random event. It is simply water chemistry seeking a new equilibrium. The more operators understand the thermodynamic forces that govern solubility, the better equipped they are to predict scaling, optimize recovery rates, and maintain reliable performance.


California’s Water Gamble: A High-Stakes Bet on an Uncertain Future

For more than a century, California has fought over water and who gets what they need. From the diversion battles in the Sacramento Delta to the decades-long controversies surrounding the Delta smelt, “water wars” have become a defining feature of the state’s political and economic landscape. These conflicts determine whether farms stay productive, cities continue to grow, and ecosystems survive. Today, California faces a new and arguably more complex chapter in that long struggle. Population growth and declining snowpack are converging to create a structural water deficit that is real. Policymakers now estimate that the state must develop the equivalent of roughly 9 million acre-feet of additional water supply by 2040, an amount comparable to two Lake Shasta reservoirs. Yet, California appears increasingly unwilling or unable to build projects on that scale.

At the heart of this is a profound shift in philosophy. The 20th century solution to water scarcity was straightforward: build dams, reservoirs, and aqueducts. Store water in wet years and release it in dry ones. That system, while far from perfect, was easy to predict and provided a degree of reliability that underpinned California’s rise as an agricultural and economic powerhouse. But in the 21st century, that model is effectively off the table. Environmental litigation, and public opposition have made the construction of major new reservoirs nearly impossible. At the same time, existing dams are being removed to restore fish habitat, further reducing surface storage capacity. The Central Valley is experiencing the consequences. Fields are fallow because water is no longer available.

With Senate Bill 72 recently passed, the state is pursuing a distributed strategy built on water restrictions, water recycling, groundwater recharge, and desalination. The plan effectively admits that new reservoirs are not possible. Each of the proposed tools has merit. Water restrictions have already reduced per-capita urban water use. Recycling can turn wastewater into a reliable supply. Recharge can store excess water underground when it is available. Desalination offers a technically feasible, if costly, new source. The challenge is the massive scale and execution risk.

Individually, none of these approaches can deliver anywhere near the volumes needed. Collectively, they might, but only if the government plan works perfectly. Recycling must expand rapidly. Recharge systems must capture erratic storm flows. Desalination must overcome cost and permitting barriers. Conservation must continue to squeeze out more gains even after decades of efficiency improvements. This is a system of interdependent pieces where failure in one area puts greater pressure on the others.

The result is a plan that is technically feasible on paper but operationally fragile. It assumes not only that multiple complex systems will be deployed successfully, but that they will perform consistently. It also assumes that political and regulatory processes, historically slow and contentious, will allow projects to move forward at the necessary pace. If those assumptions prove overly optimistic, the consequences could be significant. Reduced water availability would ripple through the state’s economy, affecting agriculture, energy, housing, and overall growth. Social impacts could follow, particularly in rural and disadvantaged communities that are already vulnerable to water shortages.


In Applications that Defeat Conventional Methods, VSEP does the Unthinkable

No other industry creates wastewater as difficult, as foul-smelling, and as treatment-resistant as animal protein processing. The odors are impossible to forget. Engineers who work with rendering plants, fish meal facilities, and slaughterhouses often joke that after spending a day around these plants, a landfill smells fresh by comparison. What begins as organic material quickly becomes a concentrated mixture of rotting proteins, fats, oils, grease, and suspended solids capable of overwhelming nearly all conventional treatment technologies. Fish processing stickwater is a perfect example. Despite its harmless-sounding name, stickwater is one of the nastiest process streams found in industry. During fish meal production, cooked fish is pressed to separate solids from liquids. Roughly 60% of the original fish mass can end up in the resulting liquid stream known as stickwater. This dark, odoriferous liquid contains dissolved proteins, fats, oils, and ultra-fine suspended organic solids that begin breaking down almost immediately. The result is a wastewater rich in valuable protein but loaded with organic foulants that create major operational headaches.

Traditionally, fish processors send stickwater to evaporators to concentrate the protein before returning it to the fish meal process. Unfortunately, the fine organic solids suspended in the stickwater have a tendency to coat evaporator heat exchange surfaces, reducing efficiency, increasing cleaning frequency, and driving up operating costs. Using conventional membrane systems is simply not possible. Biological treatment struggle and even evaporation becomes difficult to sustain. VSEP approaches the problem differently. By applying powerful vibrational shear directly at the membrane surface, VSEP continuously disrupts the concentration of solids at the membrane surface before it can establish itself. Instead of allowing proteins, fats, grease, and solids to blanket the membrane, the vibration keeps them suspended and moving.

During pilot testing on fish processing stickwater, VSEP UF successfully separated the troublesome suspended solids responsible for evaporator fouling. The system achieves an average flux of 42.8 GFD at 80% recovery while producing a permeate stream free of suspended solids and suitable for downstream concentration. The significance of this goes far beyond fish processing. Rendering wastewater contains blood proteins, emulsified grease, fats, and suspended solids capable of crippling conventional membranes. Tanneries generate wastewater containing organics, hair, fats, chemicals, and suspended solids. These streams are often described as “impossible” applications because nearly every treatment technology eventually succumbs to fouling.

Yet these are precisely the applications where VSEP has earned its reputation. When wastewater is too awful, too greasy, too dirty, too odorous, or simply too difficult for conventional treatment, VSEP often becomes the technology of last resort. Time and again, it succeeds where traditional membranes, clarifiers, biological systems, and even evaporators struggle. From rendering plants and tanneries to manure treatment and fish processing, VSEP has proven that some of the world’s most challenging wastewaters are not untreatable after all. They simply require a different kind of separator.


What Engineered Filters can Learn from Flamingos

When most people picture flamingos feeding, they imagine birds plucking small fish or insects from the water. In reality, flamingos are highly efficient filter feeders. Standing in shallow muddy water, flamingos process enormous volumes of fluid, extracting microscopic food particles, some as small as 20 microns, without clogging their biological “filters.” This efficiency depends on managing flow dynamics and preventing fouling. Flamingos feed by lowering their heads upside down into the water, submerging their uniquely shaped beaks. Their tongues function as powerful piston pumps, drawing in water laden with algae, diatoms, and tiny crustaceans. Once inside the beak, the water is forced outward through fine comb-like structures called lamellae, which act as a filtration screen. Food particles are retained, while excess water and suspended solids are expelled through alternating sides of their mouth.

Flamingos feed in highly turbid, sediment-rich conditions, settings that would foul normal filters. Yet, they continue operating seamlessly, without clogging. The key lies in hydrodynamics. Rather than relying on a static filtration surface, flamingos generate a continuous bidirectional oscillatory flow. Water is rapidly pulled in and expelled multiple times per second. This creates localized shear forces along the lamellae surfaces, preventing particles from accumulating and forming a blockage layer. In essence, flamingos avoid fouling by never allowing a boundary layer to develop.

This is the same principle used In VSEP systems, membranes are subjected to high-frequency torsional oscillation, producing intense shear at the membrane surface. This shear disrupts the formation of fouling layers, whether from suspended solids, scaling salts, or organic matter, and maintains high permeate flux even under extreme conditions. Both systems, natural and engineered, arrive at the same fundamental solution: maintain shear at the filtration interface to prevent buildup. However, there is an interesting philosophical difference. Flamingos use a size-inclusion strategy, capturing desired particles while rejecting the rest. VSEP, by contrast, operates on size exclusion, allowing clean water to pass while rejecting contaminants. Despite this inversion, the underlying challenge, sustaining throughput without fouling, is solved in nearly identical ways.

The flamingo’s feeding mechanism also highlights another similarity: self-cleaning through flow reversal. Because the flow is inherently pulsatile and oscillatory, any particles that begin to settle are immediately dislodged. This mirrors the effect of VSEP’s oscillating shear waves, which continuously sweep the membrane surface clean. From an engineering perspective, flamingos represent a biological validation of shear-enhanced filtration design. Evolution has refined this mechanism over millions of years, optimizing for efficiency, resilience, and energy use, all in some of the most challenging water conditions imaginable. In both nature and technology, the lesson is clear: efficient filtration is not just about the filter, it is about how fluid moves across it. Flamingos demonstrate that with the right combination of oscillation, shear, and flow control, even the dirtiest water can be processed continuously, effectively, and without clogging.


Nitrogen or Phosphorus in Discharge – Which one Matters?

Biogas production is expanding across Norway, Sweden, and throughout Europe. The effluent generated is typically rich in nutrients such as nitrogen and phosphorus. When released to surface waters, especially fjords or small receiving bodies of water, it can create significant environmental problems. Fjords have a stratified structure and limited mixing. This means that discharged pollutants are not diluted or flushed away easily but instead can accumulate over time, amplifying their ecological impact. This requires low levels in any discharge to prevent long term damage. The concern with nutrient discharges is eutrophication, a process in which excess nutrients stimulate rapid growth of algae and aquatic plants. While algae are a natural part of aquatic ecosystems, excessive growth will reduce water clarity, deplete dissolved oxygen affecting fish, and will produce algae toxins that are a health hazard for humans and animal life.

In biogas effluent, nitrogen concentrations can reach extremely high levels around 3000 mg/L. Regulatory frameworks in Scandinavia focus on nitrogen removal, however, phosphorus is frequently given less attention, despite its critical role in controlling algal growth. Phosphorus is actually the limiting nutrient that triggers algae growth. If there is zero phosphorus in the water, it does not matter what the level of nitrogen is, there will be no algae and aquatic plant life growth. There will always be some background phosphorus from decaying plants or fish or from residual amounts in the sediment. Because of this, the focus is on Nitrogen. But if phosphorus is limited and reduced, the nitrogen level is less important. 5 mg/L of nitrogen in a discharge would be considered clean. But with phosphorus, even very small increases can trigger rapid biological responses. Concentrations as low as 0.03 mg/L (30 parts per billion) are recognized as a tipping point where systems shift toward eutrophic conditions due to rapid algae growth.

The interaction between nitrogen and phosphorus is particularly important. While nitrogen supports algal growth, certain cyanobacteria species have the ability to fix nitrogen directly from the atmosphere. This capability means that even in water where nitrogen is zero, this algae can exponentially propagate if phosphorus is available. The result is that phosphorus effectively acts as a gatekeeper for bloom formation, while nitrogen determines the ultimate size, persistence, and severity of the bloom. When phosphorus is present, even at trace levels, and environmental conditions such as warm temperatures and low water movement are favorable, harmful algal blooms can develop and produce toxins that pose risks to both ecosystems and human health.

There are biological treatment technologies that are effective at reducing nitrogen through processes known as nitrification and denitrification. However, these systems will not remove dissolved phosphorus. As a result, effluent that meets nitrogen discharge requirements may still contain enough phosphorus to drive eutrophication, particularly in sensitive receiving waters like fjords. This has not properly been addressed in many discharge standards.

Advanced treatment like VSEP RO provide a more comprehensive solution. By physically separating dissolved constituents, VSEP RO systems can remove both nitrogen and phosphorus to extremely low levels along with all other dissolved solids. With multiple passes using RO, VSEP can reduce nitrogen to <5 mg/L and can reduce phosphorus to non-detect levels. This dual removal capability is critical for preventing eutrophication in environments where even trace nutrients can have outsized effects. This has been demonstrated several times during multiple recent pilot tests that New Logic has conducted in Norway and Sweden. The results of the most recent test can be seen in the image above. The VSEP RO is used as a primary stage, and then for the purpose of data collection, three stages of spiral RO polishing was done. The final water after this measured 0.4 mg/L nitrogen, non-detect phosphorus, and had a conductivity of 5 µS.

As understanding of nutrient dynamics continues to evolve, it is becoming clear that effective water protection strategies must address both nitrogen and phosphorus. In highly sensitive systems such as Nordic fjords, controlling phosphorus to ultra-low levels is essential, not optional. Only treatment approaches capable of achieving these thresholds can reliably prevent the cascade of impacts associated with eutrophication and harmful algal blooms.


 

Thank you for subscribing to our newsletter. I hope you find it informational and fun. You are one of 3,600 professionals and industry stakeholders who receive this newsletter each month.


Printable PDF

Primary Sidebar

About us
  • Company
  • Careers
  • Distributors
  • Events
  • News

Secondary Sidebar

New Logic Research

Subscribe to
our newsletter

Address:
2527 Aviation Way
Minden, NV 89423

775-783-7600
info@vsep.com

Copyright © New Logic Research All Rights Reserved.

Copyright © 2026 · Genesis Framework · WordPress · Log in