• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to secondary sidebar
  • Skip to footer
  • info@vsep.com
  • +1-775-783-7600
New Logic Research
  • Home
  • Technology
    • Benefits
    • VSEP System Components
    • Membrane Technology
    • Applications
    • FAQ
    • Pilot Testing
  • Products
    • Series i
      • i18 VSEP Filtration System
      • i36 VSEP Filtration System
      • i84 VSEP Filtration System
      • High Pressure Systems
    • Lab & Pilot Systems
      • Series B
      • Series LP
      • Series P50
      • Batch Titan® 1000
    • Spiral RO Systems
      • S-80 Spiral RO System
      • S-240 Spiral RO System
      • S-800 Spiral RO System
      • S-1600 Spiral RO System
      • S-3200 Spiral RO System
      • S-7200 Spiral RO System
      • S-9600 Spiral RO System
      • S-18000 Spiral RO System
      • S-28800 Spiral RO System
      • S-36000 Spiral RO System
    • VSEP Membrane Cleaners
      • NLR 103
      • NLR 202
      • NLR 404
      • NLR 505
      • NLR 550
      • NLR 707
      • NLR 757
      • NLR 758
      • NLR 759
  • Industries
    • Animal Protein and By-Products
      • Aquaculture Wastewater
      • Fish Meal Stickwater
      • Fish Processing Wastewater
      • Leather Tannery Wastewater
      • Rendering Wastewater Treatment
      • Slaughterhouse Wastewater
    • Biogas Effluent
    • Brine and Brackish Water
      • RO Reject / Brine Minimization
      • Zero Liquid Discharge (ZLD)
    • Food and Beverage
      • Beer Bottoms Filtration
      • Beverage Production
      • Bottled Water
      • Coffee Extract Dewatering
      • Cooked Corn Wastewater
      • Fruit Juice Clarification
      • Olive Processing
      • Palm Oil POME Treatment
      • Sugar Juice Clarification
      • Whey Wastewater
      • Winery Wastewater
    • Industrial Wastewater
      • Calcium Chloride Recovery
      • Colloidal Silica Dewatering
      • Glycol Recovery
      • Hot Rolled Steel Wastewater
      • Indigo Dye Wastewater
      • Laundry Wastewater
      • PET Recycling Wastewater
      • PFAS Remediation and Treatment
      • Sodium Sulfate Recovery
      • Textile Dye Wastewater
      • Yeast Wastewater
    • Landfill Leachate Treatment
      • PFAS Removal for Landfill Leachate
    • Manure Management
    • Metal Finishing Wastewater
      • Aluminum Can Wastewater
      • Anodizing Wastewater
      • Electroplating Wastewater
      • Galvanizing Wastewater
      • Powder Coating Wastewater
    • Mining and Metals
      • Acid Purification and Recycling
      • Copper Refining Wastewater
      • Gold Tailings Pond Water
      • Gypsum Stack Wastewater
      • Iron Tailings Pond Water
      • Lithium Extraction
      • Manganese Ferroalloy Wastewater
      • Phosphoric Acid Filtration
      • Platinum Group Metals
      • Rare Earth Elements
      • Red Mud Dewatering
      • Zinc Smelting Wastewater
    • Municipal Wastewater
      • Indirect Potable Reuse
      • POTW Discharge
      • Reclaimed Water Treatment
      • Remote Community Wastewater
    • Oil and Gas Applications
      • Algae Dewatering & Harvesting
      • Desalter Effluent
      • Drilling Mud Treatment
      • Fuel Storage Tank Water
      • Frac Water
      • Oily Wastewater
      • Produced Water
      • Slop Oil Treatment
      • Stripped Sour Water
    • Pigment Dewatering
      • Calcium Carbonate Dewatering
      • Carbon Black
      • Iron Oxide Pigment
      • Kaolin Clay Dewatering
      • Metal Chromate Pigment
      • Titanium Dioxide Filtration
    • Polymer Manufacturing
    • Power Plant Effluent
      • Cooling Tower Blowdown
      • FGD Wastewater
      • Fly Ash Leachate Treatment
      • Nuclear Power
    • Pulp & Paper
      • Black Liquor
      • Box Plant Wastewater
      • End of Pipe Wastewater
      • Hardboard Wastewater
      • MDF Wastewater
      • Paper Coating Recovery
      • Whitewater Treatment
    • Semiconductor
      • Gallium Arsenide Wastewater
      • HF Wastewater
      • PCB Wastewater
      • Scrubber Wastewater
      • Ultrapure Water
      • Wafer Fabrication Wastewater
    • Stillage and Vinasse Dewatering
      • Glycerol Recovery from Stillage
  • Company
    • Careers
    • Contact
    • Distributors
    • Join our Mailing List
    • News
    • Privacy Policy
    • Sitemap
  • Downloads
    • Case Studies & Application Notes
    • Technical Articles Featuring VSEP
    • VSEP Brochure
    • VSEP Video Clips
    • VSEP System Drawings
    • New Logic Customer Forms

News

Using VSEP to Treat Coolant Wastewater from an Automotive Facility

October 25, 2005

Introduction

Wastewater from the production of automotive parts can be difficult to treat due to its varied chemical composition. This type of wastewater contains elevated levels of COD that need to be reduced to meet local sewer specifications. The typical treatment scheme could consist of chemical treatment followed by a lot of pre-treatment steps and eventually a reverse osmosis membrane system. This type of treatment scheme can take up quite a bit of space in a facility and have high operating costs due to the chemical addition.

VSEP Membrane Technology

An innovative technology being used to treat coolant wastewater is known as VSEP (Vibratory Shear Enhanced Processing). Developed by New Logic Research, Inc. of Minden, NV. This revolutionary technology has made it possible to filter streams containing a variety of components without the fouling problems exhibited by conventional membrane systems. This advanced membrane system does not only remove the oil and grease but also significantly reduces the COD. The result is a crystal-clear water stream and a concentrated sludge.

The main difference between VSEP and traditional crossflow membrane filtration is the mechanism by which the foulants are prevented from accumulating on the membrane surface. A traditional crossflow system relies on the fluid velocity of the feed material alone to create shear forces needed to reduce fouling. This mechanism assists in slowing the fouling process but because a thin, stagnant boundary layer remains on the membrane surface, the foulants from the stream will accumulate over time and deteriorate the throughput rate. On the other hand, a VSEP system utilizes a patented vibratory drive mechanism that vibrates the membrane surface creating a shear force that disrupts the boundary layer. The resulting motion of the vibration drive is a _ inch peak to peak displacement, which constantly repels solids and other foulants away from the membrane surface. This mechanism enables the filter module to maintain higher, sustained throughput rates and process larger volumes of material economically.

CASE STUDY

 Industrial Installation in Shanghai

New Logic has recently installed an industrial VSEP system into an automotive engine manufacturing facility in Shanghai. This unit is used in conjunction with a nanofiltration tubular system to achieve an overall reduction in COD from 300,000 mg/L down to 3,000 mg/L.

The purpose of the installation is to reduce the volume of wastewater prior to sending it to a centralized wastewater treatment plant. Due to more stringent environmental regulations, this facility was faced with paying excessive fines or finding a treatment method to meet the required discharge specifications. The VSEP was selected primarily due to its compact footprint, modular system design and effective filtration of a stream that fouled other membrane systems in minutes.

Lab and Pilot Testing

The initial testing on the wastewater was used to identify a membrane that would not foul and yet still provide a significant reduction in COD. The membrane that was selected from the screening tests is a nanofiltration membrane with a 40-60% NaCl rejection. The membrane is known for its fouling resistance and can withstand cleaning routines involving both acidic and caustic cleaners. Although reverse osmosis membranes were able to provide a slightly better reduction in the COD they were limited in terms of recovery and produced much lower flow rates resulting in poor process economics. The nanofilter selected was able to provide a significant reduction in COD, economical throughput (flux rates) and a resistance to the foulants.

The first phase of testing was done in lab or L mode with a single sheet of membrane. The data collected gives an idea of the anticipated flux relative to the amount of permeate recovered. It was also determined that at a 75-80% permeate recovery the membrane was able to reduce 90% of the COD. The resulting effluent contained on average 30,000 mg/L from a starting feed of 300,000 mg/L.

Pilot scale testing or P mode at the customer’s facility followed the first phase of testing. This test involved using a small filter pack containing approximately 16.5 square feet. This system was used to collect data that simulates more of the type of performance of an industrial machine. Again, the data that was most important in the initial P test was the flux versus the % recovery. The results of the two tests are shown in the following graph.

As you can see from the graph the lab mode results show a slightly higher flux rate than the P mode testing. This is primarily due to the manner in which each test was run. The lab scale test was completed with a small (15 gallon) sample while the pilot test was completed with more of a slipstream of feed material. The smaller sample only has a finite amount of foulants and may not foul the membrane as rapidly as if the feed was constantly replenished with new foulants. The main purpose of the two tests is different with the pilot data weighted more heavily for an average flux determination.

The pilot test proceeded for approximately one month and showed that the flux was stable and the system could be flushed daily with warm water to maintain an economical average flow rate. The data from some of the pilot testing is shown in Figure 3. Over this pilot test period the machine was exposed to the variations that can occur with this type of waste stream. The results not only confirmed the reliability of the membrane but also provided our engineering team with the information needed to design an industrial VSEP system.

Industrial Installation

The industrial VSEP system was designed using 450 square feet of membrane area. The system included a feed pump, pre-filtration and CIP all contained on a single skid. The VSEP is fed using a vertical centrifugal pump with a feed pressure of 300-350 psi. The wastewater is collected in two separate 40 m3 feed tanks and then pumped into a smaller tank that is approximately 10 m3. This tank is operated in batch mode through the VSEP with the permeate going to the tubular membrane system for final COD reduction. The final permeate from the tubular system is sent to the sewer, but the customer is investigating re-use. The concentrate is volume reduced to 20-25% of the original volume and is sent to the central wastewater treatment plant. Figure 4 shows a simplified flow diagram for the VSEP portion of the system.

The performance of the industrial unit corresponded well with the pilot test results. The system did achieve the desired 90% reduction of COD. The results of the first couple of hours of operation are shown in Figure 5. The preliminary start-up data shows that the flux is stable and slightly higher than the results of the P test but the membrane is still very new and so we would expect the flux to level off closer to 18-20 GFD.

The unit is only designed to operate for 16 hours per day with a warm water flush at the end of the day prior to shut down. A chemical cleaning should only be needed once per week to reset the membrane and prevent accumulation of foulants present in low concentrations in the feed stream. The cleaning is completed with a small CIP tank and a low-pressure feed pump. The cleaning solution is recirculated through the filter pack for anywhere from 20 to 30 minutes. This procedure followed by a flush is all that is needed for the system to be ready to run on the wastewater.

CONCLUSIONS

VSEP in conjunction with the appropriate nanofiltration membrane has been shown to be effective in the treatment of coolant wastewater. With a compact footprint, modular design and reliable operation the VSEP system was able to meet the stringent process objectives for a stream that would typically require a much more complicated treatment system.

For more information about how V✧SEP can help you, please contact us at info@vsep.com.

To keep up with industry news and New Logic Research subscribe to our newsletter below.

To follow New Logic Research on LinkedIn Click Here

Print or Download PDF

Primary Sidebar

About us
  • Company
  • Careers
  • Distributors
  • Events
  • News

Secondary Sidebar

New Logic Research

Subscribe to
our newsletter

Address:
2527 Aviation Way
Minden, NV 89423

775-783-7600
info@vsep.com

Copyright © New Logic Research All Rights Reserved.

Copyright © 2026 · Genesis Framework · WordPress · Log in